PC-900 Plus Vital Signs Monitor
PC-900 Plus Vital Signs Monitor
Couldn't load pickup availability
- Display options: Waveform, list or trend graph
- Simple operation and fast data analysis
- Storage space for 2,000 data sets of SpO2 measurements
- Integrated alarm functions
- Dimensions: 360 x 320 x 410 mm (L x W x H)
PC-900 Plus Vital Signs Monitor
The PC-900 Plus Vital Signs Monitor from Lepu Medical allows precise monitoring of essential parameters. With a 7-inch touchscreen displaying SpO2/EKG waveforms and numerical values, the desktop design offers user-friendly operation. With impressive data storage capacity, the monitor captures up to 12000 results of non-invasive blood pressure (NIBP), 2000 data points of oxygen saturation (SpO2), and event records. Historic patiet data can be easily reviewed in waveforms, lists, or trend charts. The device's flexibility allows for individual configuration among various vital parameters such as SpO2, NIBP, temperature, and ECG. By simply connecting to a computer via a USB cable, data can be exported and software updates can be performed.
Product Details
- PC-900 Plus Vital Signs Monitor from Lepu Medical
- 7-inch touchscreen for displaying SpO2/ECG waveforms and numerical values
- Convenient desktop design with an easy-to-use interface
- Storage for up to 12,000 blood pressure results, 2,000 SpO2 results and event records
- Historic patient data can be reviewed in waveform, list, or trend graph
- Convenient data export and software update via USB cable
- Multi-stage audible and visual alarm functions, as well as nurse call
- Flexible configurations for SpO2, NIBP, TEMP and ECG
- Complies with the standard IEC 60601-1
- Delivery Contents: Patient monitor, SpO2 finger clip sensor for adults, NIBP cuff for adults (25-35 cm), power cable
Technical Specifications
| Display | 7-inch colour display |
| Dimensions (L x W x H) | 360 x 320 x 410 mm |
| Battery | Lithium battery (4400 mAh) |
| Operating Conditions | Ambient temperature: 5 - 40 °C Humidity: 30 - 80% Air pressure: 70 kP - 106 kPa |
| Storage Conditions | Temperature: -20 - 60 °C Humidity: 10 - 95% Air pressure: 50.0 kPa - 107.4 kPa |
| NIBP Measurement | |
| Measurement Method | Oscillometric method |
| Measurement Range for Pneumatic Pressure | 0 mmHg - 300 mmHg |
| Accuracy of Pressure Measurement | +3 mmHg |
| Cuff Inflation Time | < 10 seconds |
| Average Measurement Duration | < 90 seconds |
| Deflation Time | < 2 seconds |
| Overpressure Protection | Adults: < 300 mmHg Children: < 240 mmHg Infants: < 150 mmHg |
| Measurement Accuracy | Mean deviation: +5 mmHg Standard deviation: 8 mmHg |
| SpO2 Measurement | |
| Probe | LED with dual wavelength |
| Wavelength | Red light: 663 nm Infrared light: 890nm (optional) |
| Max. Optical Output Power | <2 mW (max. average) |
| Measurement Range | 35 to 100% |
| Measurement Accuracy | ≤2% for SpO2 range from 70% to 100% (according to ISO 80601-2-61) |
| Pulse Rate Measurement | |
| Measurement Range | 30 bpm to 240 bpm |
| Measurement Accuracy | +2 bpm or +2%, whichever is greater |
| ECG Measurement | |
| Input Signal Range in Amplitude | +0.5 - 5 mVp |
| Heart Rate Display Range | 15 beats per minute to 350 beats per minute |
| Heart Rate Accuracy | +1% or +2 bpm |
| Heart Rate Notification | Notification of the last 8 heartbeats with RR intervals within allowable limits |
| Recovery Time during Defibrillation | <10 seconds |
| Noise Level | <30 μVp-p |
| Heart Rate Alarm Delay | <10 seconds |
Share