PC-900 Plus Vital Signs Monitor

PC-900 Plus Vital Signs Monitor

Regular price £1,143.62
Regular price £0.00 Sale price £1,143.62
Sale Sold out
Product overview
  • Display options: Waveform, list or trend graph
  • Simple operation and fast data analysis
  • Storage space for 2,000 data sets of SpO2 measurements
  • Integrated alarm functions
  • Dimensions: 360 x 320 x 410 mm (L x W x H)

PC-900 Plus Vital Signs Monitor

The PC-900 Plus Vital Signs Monitor from Lepu Medical allows precise monitoring of essential parameters. With a 7-inch touchscreen displaying SpO2/EKG waveforms and numerical values, the desktop design offers user-friendly operation. With impressive data storage capacity, the monitor captures up to 12000 results of non-invasive blood pressure (NIBP), 2000 data points of oxygen saturation (SpO2), and event records. Historic patiet data can be easily reviewed in waveforms, lists, or trend charts. The device's flexibility allows for individual configuration among various vital parameters such as SpO2, NIBP, temperature, and ECG. By simply connecting to a computer via a USB cable, data can be exported and software updates can be performed. 

 

Product Details

  • PC-900 Plus Vital Signs Monitor from Lepu Medical
  • 7-inch touchscreen for displaying SpO2/ECG waveforms and numerical values
  • Convenient desktop design with an easy-to-use interface
  • Storage for up to 12,000 blood pressure results, 2,000 SpO2 results and event records
  • Historic patient data can be reviewed in waveform, list, or trend graph
  • Convenient data export and software update via USB cable
  • Multi-stage audible and visual alarm functions, as well as nurse call
  • Flexible configurations for SpO2, NIBP, TEMP and ECG
  • Complies with the standard IEC 60601-1
  • Delivery Contents: Patient monitor, SpO2 finger clip sensor for adults, NIBP cuff for adults (25-35 cm), power cable

 

Technical Specifications

Display 7-inch colour display
Dimensions (L x W x H) 360 x 320 x 410 mm
Battery Lithium battery (4400 mAh)
Operating Conditions Ambient temperature: 5 - 40 °C
Humidity: 30 - 80%
Air pressure: 70 kP - 106 kPa
Storage Conditions Temperature: -20 - 60 °C
Humidity: 10 - 95%
Air pressure: 50.0 kPa - 107.4 kPa
NIBP Measurement
Measurement Method Oscillometric method
Measurement Range for Pneumatic Pressure 0 mmHg - 300 mmHg
Accuracy of Pressure Measurement +3 mmHg
Cuff Inflation Time < 10 seconds
Average Measurement Duration < 90 seconds
Deflation Time < 2 seconds
Overpressure Protection Adults: < 300 mmHg
Children: < 240 mmHg
Infants: < 150 mmHg
Measurement Accuracy Mean deviation: +5 mmHg
Standard deviation: 8 mmHg
SpO2 Measurement
Probe LED with dual wavelength
Wavelength Red light: 663 nm
Infrared light: 890nm (optional)
Max. Optical Output Power <2 mW (max. average)
Measurement Range 35 to 100%
Measurement Accuracy ≤2% for SpO2 range from 70% to 100% (according to ISO 80601-2-61)
Pulse Rate Measurement
Measurement Range 30 bpm to 240 bpm
Measurement Accuracy +2 bpm or +2%, whichever is greater
ECG Measurement
Input Signal Range in Amplitude +0.5 - 5 mVp
Heart Rate Display Range 15 beats per minute to 350 beats per minute
Heart Rate Accuracy +1% or +2 bpm
Heart Rate Notification Notification of the last 8 heartbeats with RR intervals within allowable limits
Recovery Time during Defibrillation <10 seconds
Noise Level <30 μVp-p
Heart Rate Alarm Delay <10 seconds